Legrand RX3 RCCB, 30mA Sensitivity, 230V AC (Double Pole)
on orders above ₹50K

| Brand | Legrand |
|---|---|
| Type | RCCBs |
| Options | 25A, 40A, 63A |
Legrand RX³ Four Pole RCCB protects three-phase 415V installations against earth leakage. It constantly compares the current flowing through all three phases and the neutral, and switches off the supply as soon as current leaks to earth – for example through damaged insulation, a faulty appliance or a person touching a live part. Its 30mA sensitivity is the standard level for protecting people from electric shock.
It takes 4 modules (71.2 mm) on a standard DIN rail, with touch-proof IP20 terminals for safer wiring and a front test button to check it is working. Choose 25A, 40A or 63A to match your installation. Please note an RCCB protects against earth leakage only – it does not protect against overload or short circuit, so it must always be used with suitable MCBs.
| Specification | 25A | 40A | 63A |
|---|---|---|---|
| Product Code | 402519 | 402520 | 402521 |
| Rated Current | 25A | 40A | 63A |
| Suitable For | Smaller three-phase installations | Medium homes, small commercial units | Larger homes and commercial loads |
| Brand / Range | Legrand RX³ | ||
| Poles | 4 Pole (3 Phase + Neutral) | ||
| Sensitivity | 30mA | ||
| Type | Type AC (sinusoidal AC leakage) | ||
| Voltage | 400 / 415V AC, 50 Hz | ||
| Conditional Short-Circuit Rating | 10 kA (with suitable upstream MCB or fuse) | ||
| Width | 4 modules (71.2 mm) | ||
| Mounting | 35 mm DIN rail | ||
| Terminals | Up to 35 sq mm rigid cable; IP20 touch-proof; prong and fork busbar compatible | ||
| Sold Separately | MCBs, distribution board |
No. An RCCB only protects against earth leakage. It must be used together with suitable MCBs, which protect the wiring against overload and short circuit.
30mA is the standard sensitivity for protecting people from electric shock. The danger to a person is the same whether the supply is single-phase or three-phase, so the same 30mA level is used.
Yes. The RCCB works by comparing the current in the three phases with the current returning through the neutral. If the neutral is not connected through the RCCB, it cannot detect leakage correctly and may not work as intended.
Type AC RCCBs detect standard alternating-current leakage, which suits typical lighting, heating and general household loads. Some modern equipment with electronic drives (such as certain inverter appliances or EV chargers) may need a Type A RCCB – check the equipment manufacturer's advice.
25A suits smaller three-phase installations, 40A suits most medium-sized homes and small commercial units, and 63A suits larger installations. The RCCB rating should be equal to or higher than the main MCB that protects it – your electrician can confirm the right size.
No. Never run a continuous load above the RCCB's rating (25A, 40A or 63A). Doing so can overheat the contacts and make the device unsafe.